Contents
Images
Upload your image
DSS Images Other Images
Related articles
The Pul-3 catalogue of 58483 stars in the Tycho-2 system A catalogue of positions and proper motions of 58483 stars (Pul-3) hasbeen constructed at the Pulkovo observatory. The Pul-3 is based on theresults of measurements of photographic plates with galaxies (Deutsch'splan). All plates were taken using the Pulkovo Normal Astrograph (thefirst epoch is in the 1950s and the second epoch is in the 1970s).The Pul-3 catalogue contains stars of mainly 12 to 16.5 mag in 146fields with galaxies in the declination zone from -5o to+85o. The Tycho-2 has been used as a reference catalogue.The mean epoch of the Pul-3 is 1963.25. The internal positional accuracyof the Pul-3 catalogue at the mean epoch of observations is ±80mas. The accuracy of the proper motions is mostly within ±3mas/yr to ±12 mas/yr. Comparisons of the Pul-3 with Tycho-2 andARIHIP have been done at the mean epoch of the Pul-3. The Pul-3 externalpositional accuracy relative to Tycho-2 is ±150 mas.The catalogue is only available in electronic form at the CDS viaanonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/418/357
| Two-colour photometry for 9473 components of close Hipparcos double and multiple stars Using observations obtained with the Tycho instrument of the ESAHipparcos satellite, a two-colour photometry is produced for componentsof more than 7 000 Hipparcos double and multiple stars with angularseparations 0.1 to 2.5 arcsec. We publish 9473 components of 5173systems with separations above 0.3 arcsec. The majority of them did nothave Tycho photometry in the Hipparcos catalogue. The magnitudes arederived in the Tycho B_T and V_T passbands, similar to the Johnsonpassbands. Photometrically resolved components of the binaries withstatistically significant trigonometric parallaxes can be put on an HRdiagram, the majority of them for the first time. Based on observationsmade with the ESA Hipparcos satellite.
| GPM1 - a catalog of absolute proper motions of stars with respect to galaxies The description of the first version of the General Compiled Catalogueof Absolute Proper Motions (GPM1) for a sample of HIPPARCOS stars,derived with respect to galaxies within the plan called Catalogue ofFaint Stars (KSZ, Deutch 1952), is presented. The principal aim of theGPM1 construction was to provide absolute proper motions of stars todetermine the rotation of the HIPPARCOS system. The GPM1 cataloguecontains 977 HIPPARCOS Input Catalogue stars with V magnitudes $5^m -11^m in 180 fields north of -25 degrees of declination. The accuracy ofthe proper motions is 8 mas/yr (milliarcseconds per year). Comparison ofproper motions of GPM1 with those of the PPM and ACRS was performed andanalyzed with respect to systematic errors caused by spurious rotationof the FK5 system. The standard errors show that the rotation may bedetermined with an accuracy better than 1 mas/yr. Catalog is onlyavailable in electronic form at the CDS via anonymous ftpcdsarc.u-strasbg.fr or ftp 130.79.128.5.
| GPM - compiled catalogue of absolute proper motions of stars in selected areas of sky with galaxies. Not Available
|
Submit a new article
Related links
Submit a new link
Member of following groups:
|
Observation and Astrometry data
Constellation: | Πήγασος |
Right ascension: | 22h39m15.83s |
Declination: | +33°53'22.1" |
Apparent magnitude: | 8.877 |
Distance: | 458.716 parsecs |
Proper motion RA: | -9.2 |
Proper motion Dec: | -6.3 |
B-T magnitude: | 9.527 |
V-T magnitude: | 8.931 |
Catalogs and designations:
|